Panasonic WV-CL920A Security Camera User Manual


 
-27-
5. Electronic Sensitivity Enhancement
(SENS UP)
There are two modes for SENS UP.
AUTO: If you select x32 AUTO, for example, the
sensitivity is raised automatically to x32 max.
When AUTO is selected, AGC is automatically
set to ON.
FIX: If you select x64 FIX, for example, the sensitiv-
ity is raised to just x64.
Move the cursor to the SENS UP parameter and select
the parameter for electronic sensitivity enhancement.
The preset values for SENS UP (electronic sensitivity
enhancement) change by pressing or as fol-
lows:
** CAM SET UP **
CAMERA ID OFF
ALC/ELC ALC
SHUTTER OFF
AGC ON (DNR-H)
SENS UP OFF
SYNC INT
WHITE BAL ATW1
MOTION DET OFF
LENS DRIVE DC
END SET UP ENABLE
X2 AUTO
OFF
X4 AUTO X6 AUTO X10 AUTO
X32 FIXX64 FIX X16 FIX X10 FIX X6 FIX X4 FIX X2 FIX OFF
X16 AUTO
X32 AUTO
Notes:
While the SENS UP function is selected, noise,
spots or a whitish phenomenon may appear in the
picture when the sensitivity of the camera is
increased. This is a normal phenomenon.
x64FIX does not appear for the SENS UP parame-
ter on the system controller setup menu.
• In case of using the WV-CU204 or WV-CU254
Controller, status does not appear correctly for the
SENS UP parameter on the setup menu.