C2969M-B (8/10) 5
NOTES:
• Pelco recommends connecting the camera to a network that uses a Dynamic Host Configuration
Protocol (DHCP) server to address devices.
• Do not use a hub in the network setup of the camera.
• To secure access to the IP camera, place the camera behind a firewall when it is connected to a
network.
ì
Relay and Alarm Connections: One relay that can be used to control an external circuit, and one
alarm for physical input into the system.
î
Accessory Port: For use with compatible Pelco accessories.
ï
RJ-45 Network Port: Connects the camera to the IP network.
ñ
24 VAC Power Wires: 24 VAC power source for the camera system. This is required for heater
operation.
ó
Auto Back Focus Button: Sets the auto back focus mechanism. Press the button once to center the
auto back focus mechanism and to fully open the iris. Press and hold the button for three seconds to
start the auto back focus mechanism and focus the camera.
r
NTSC/PAL Button: Toggles the service port between NTSC and PAL formats.
s
Power LED: Glows solid amber and then glows solid green during and after the configuration
sequence. The LED can be disabled through the user interface. If this LED glows red (solid or flashing),
contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981
(international) for assistance.
t
Reset Button: Reboots the camera or restores the cameras factory default settings. This button is
recessed. Using a small tool, such as a paper clip, press and release the reset button once to reboot
the camera. Press and hold the reset button for 10 seconds to restore the camera to the factory
default settings.
u
Service Port: Outputs analog video. Use this port at the installation site to set up the field of view
and to focus the camera. When a service cable is connected to the camera, video to the IP stream is
disabled.
~í
Micro SD Card Slot: Saves a snapshot image to a micro SD card based on alarm activity.
~â
Auto Iris Lens Connector: Controls the auto iris lens. Insert the 4-pin connector from the DC drive
auto iris lens into this connector.
~ä
Lens Mount: Fits a standard CS-mount lens. Use a megapixel lens with the IE Series and IEE Series
megapixel cameras. A standard definition lens installed on a megapixel camera will limit the
resolution of the camera and create poor image quality.