4 C494M-D (1/96)
Installation
Before installing the HS2000 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera
and lens.
The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure.
NOTE:
The four (4) fasteners required to secure the HS2000 to a wall (minimum 3/8” diameter recommended) are not supplied
CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall (tight to the ceiling), perform the following steps:
1. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).
2. Using the mounting bracket or the template provided, mark and drill holes in the mounting surface.
3. Attach the enclosure with the required fasteners.
4. Route the required cables through the back or top.
5. Mount the camera/lens to the tilt table.
6. Make all appropriate connections (i.e., camera power, video [coax], lens).
7. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in place.
8. Replace the cover and check that all components clear. Secure with the 1/4-20 “Tampruf” screw provided.
NOTE:
A plate is provided to prevent access through the top of this enclosure. If needed, it is mounted with the mounting bracket using the
same mounting holes and hardware.
MID-WALL MOUNTING
To mount the HS2000 enclosure mid-wall, use the optional hood, HS2000H, and perform the following steps:
1. Determine the position for the hood. Using it as a template, mark and drill holes in the mounting surface.
2. Attach the hood with the required fasteners (minimum 3/8" diameter recommended).
3. Continue with steps 1-8 in Section 4.1.
WINDOW INSTALLATION
The HS2000 is provided with a clear Lexan 1/4" thick viewing window. An optional smoked window, HS200010019, is available.
Instructions for installing the optional smoked window are as follows:
1. Remove the cover from the mounting bracket. A special socket is provided.
2. Remove the four (4) 1/4-20 elastic locknuts and 1/4" flat washers.
3. Remove the window.
4. Remove the protective coatings from the new window and place the window over the four (4) 1/4-20 studs.
5. Replace the hardware and replace the cover.