Ricoh FV-L500B1 Digital Camera User Manual


 
7/31
FV-L500B1
User’s Guide Rev. 1.01
2.1.2 Vertical Timing
2.1.2.1 Normal Full Scanning (Setting 10H: 1XX00XXX, 11H: XXX0X000)
1 H = 30.063 μs, 16.000 Hz
2.1.2.2 Partial Full Scanning (Setting 10H: 1XX01XXX, 11H: XXX0X000)
1 H = 30.063 μs, 16.100 Hz
By transferring the blanking period pixels at a high rate, the frame rate of the partial full scanning can
be increased compared to that of the normal full scanning.
Video out
FVAL
2079H
One vertical (1V)
2058H21H
2058H21H
Video output active term
1
2
2057
2058
21H
Vertical
blanking
Vertical
blanking
21H
LVAL
DVAL
Video out
FVAL
2066H
One vertical (1V)
2058H8H
2058H8H
Video output active term
1
2
2057
2058
8H
Vertical
blanking
Vertical
blanking
8H
LVAL
DVAL