Samsung SOC-4160 Camera Lens User Manual


 
COLOR CCD CAMERA User Guide
14
COLOR CCD CAMERA User Guide
15
• 
Whenmakingacontrolsystemtocontrolthecamera,pleaseusetothe
protocol(STW(SPD),PELCO-P,PELCO-D,VICON,PANASONIC,BOSCH,HONEYELL,SEC).
•WhenyouconnectingtoRS-485CONTROLTERMINAL,pleasepeelofftheouter
skininsidetheRS-485CONTROLTERMINAL.
•
IncaseofSCC-101connection,changecommunicationmodeto8-E-1at Communication
configurationmenu.(Formoreinformation,refertoSCC-101manual.)
Notes
Using Coaxial Communications
DVD
SOC-4160
Coaxial Communications System
OSD Control method
DVR
Distance
Recommended Cable Specification
300m 3C2V(RG-59/U)
450m 5C2V(RG-6/U)
600m 7C2V(RG-11/U)
– Video Cable
The camera's video output port is connected to the monitor with a BNC coaxial cable,
shown below : If the distance between the camera and the monitor exceeds the
recommended maximum, please use an auxiliary video amp.
•Ifthecameraiscontrolledthroughcoaxialcommunication,pleaseuseavideoamp
intended for coaxial communications. Regular video amps do not transfer coaxial
signals.
Notes
Using RS-485 communication will enable you to control the OSD menu from a SAMSUNG
TECHWIN System Controller or DVR.
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1) SERIAL CABLE RS-485 CONVERTER RS-485
CONTROL CABLE
Connecting to RS-485 Control Cable
CONTROL CABLE SPEC
WHITE (TRX+) RS-485+
BLCAK (TRX-) RS-485-
* RS-485 Communication establishment initial value
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL WHITE (TRX+)
(-) CONNECTION TERMINAL BLACK (TRX-)
Item
Camera ID BAUD RATE UART MODE RET PKT
Initial value
1 9600 8-NONE-1 ENABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
WHITE (TRX+)
BLACK (TRX
-
)
CAMERA DVR CONTROLLER
SET MENU/ENTER OSD KEY
UP UP KEY JOYSTICK UP
DOWN DOWN KEY JOYSTICK DOWN
LEFT LEFT KEY JOYSTICK LEFT
RIGHT RIGHT KEY JOYSTICK RIGHT
RS-485 communication control
Connection
•
:BNC
•
----:RS-485