Sanyo VCB-3572IRP Camcorder User Manual


 
SETTINGS
Electronic iris function setting
Use a manual or fixed iris lens and set the lens
aperture to the shortest F stop. Set the EI/BLC
switch to EI-ON position.
Note:
Please refer to the specifications for dynamic
range of the electronic iris.
CAUTION:
The electronic iris is suitable for normal indoor use. When the EI/BLC
switch is set to the EI-ON position, do not use an auto-iris lens.
If used under fluorescent light, the image may flicker. In such a
case, change to incandescent lighting or set the EI/BLC switch to
the OFF position and use an auto-iris lens.
When shooting bright subjects, pay attention to the light angle in
order to avoid or minimize the smear phenomenon effect.
When using an auto-iris lens (for indoor/outdoor use)
Set the EI/BLC switch to the OFF position.
CAUTION:
If conditions are outside the electronic iris operation range or more
than the maximum illumination, it will cause saturation of the CCD. In
that case, use a manual iris lens.
Lens iris adjustment
If using a DC type auto-iris lens, you will need to set the LEVEL
(VR401) volume when shooting in the conditions described below.
L (counterclockwise): To decrease the contrast
H (clockwise): To increase the contrast
If shooting simultaneously in a dark room
and through a bright window.
If the subject background is extremely
bright or dark.
If the brightness of the picture on the
monitor is not correct.
ON
OFF
ON
EI
BLC
L
E
V
E
L
LH
VR401
L72H2/XE2 GB 1999, 3, 2
10 English