Sanyo VCC-MD300P Security Camera User Manual


 
− 15 −
Communications Protocol
[5] Command List for MD400 and 300
Message
System CAMERA TYPE Unit A0 01 01 00 CS FF
CAMERA TYPE Dome A0 01 01 01 CS FF Sanyo Dome Camera ID
CAMERA TYPE Zoom A0 01 01 02 CS FF Sanyo Dome Camera ID
All Initial A0 01 0A CS FF Initialization of Unadjusted EEPROM Values (Set to Factory Defaults)
All Menu Initial A0 01 0B CS FF Initialization of All Menu Settings
Lens Initial A0 01 0C CS FF Detection of initial lens position
Reset A0 01 0D CS FF Restarting camera (Saves the setting value)
Menu Initial A0 01 0E CS FF Initialization of menu settings other than privacy mask settings
Zoom Tele A0 02 05 CS FF
Wide A0 02 06 CS FF
Tele/Wide Stop A0 02 07 CS FF
Tele/Wide Speed A0 02 08 0p CS FF p: Speed 1-4 during Tele and Wide commands (1: Slow-4: Fast [Initial value: 3])
Direct A0 02 09 0p 0q 0r CS FF pqr: Direct Position
MD400, 0: Wide, 1829: 22x (optical), 2069: 352x (digital)
MD300, 0: Wide, 2248: 22x (optical), 2488: 352x (digital)
Digital Zoom Tele Limiter command needs to be sent before moving to digital zoom field.
Digital Zoom Tele Limiter A0 02 18 0p CS FF p: Maximum digital zoom magnification (0: x0 [Initial value], 1: x2, 2: x4, 3: x8, 4: x16)
V-Reso.UP OFF/ON A0 02 1F 0p CS FF p: Increased vertical sensitivity settings during digital zoom OFF/ON (0: OFF, 1: ON)
VIEW ANGLE Set *1 A0 02 23 0p CS FF p: Vignette Reduction Mode Settings (0: OFF, 1: OVER0
1.05x, 2: OVER1
1.06x,
3: OVER 2
1.07x, 4: OVER 3
1.08x, 5: OVER4
1.09x, 6: OVER5
1.10x) (Initial value: 0)
Zoom Preset ON A0 02 28 CS FF Moves the zoom position to the optical TELE edge
Zoom Preset OFF A0 02 29 CS FF Returns the zoom position to the position before the “Zoom Preset ON” operation
Focus Auto Focus ON A0 03 00 CS FF
Manual Focus ON A0 03 01 CS FF
One Push Trigger A0 03 03 CS FF Operates the auto focus operation once
Far A0 03 05 CS FF
Near A0 03 06 CS FF
Far/Near Stop A0 03 07 CS FF
Far/Near Speed A0 03 08 0p CS FF p: Speed 1-4 during Far and Near commands (1: Slow-4: Fast (Initial value: 2))
Direct A0 03 09 0p 0q 0r CS FF pqr: Direct Position (VCC-MD400 0:Far 3524:Near VCC-MD300 0:Far 4008:Near)
Near Limiter A0 03 0E 0p CS FF p: Subject distance limit during auto focus and manual focus
(0: 10 cm, 1: 30cm, 2: 50 cm, 3: 1 m [Initial value], 4: 3 m, 5: 5 m)
Auto Focus Sensitivity A0 03 10 0p CS FF p: Auto focus restart sensitivity settings (0: LOW, 1: HI [Initial value], 2: HI+)
High+ automatically restarts every 10 seconds (only TELE side) in addition to restarting the change in
subject
Focus Area A0 03 13 0p CS FF Settings Determining Auto Focus Areas 1-3
1: Entire screen-3: Only center of the screen (Initial value: 2)
White
Balance
ATW A0 04 00 CS FF Auto White Balance Mode (Same as "0" in WB Mode)
MWB A0 04 01 CS FF Manual White Balance Mode (Same as "1" in WB Mode)
One Push Trigger (AWC Set) A0 04 03 CS FF Executes OnePush in AWC Mode (Note 7)
AWC Reset A0 04 04 CS FF Returns to the original mode only after executing the OnePush Trigger command
ATW Smart OFF/ON A0 04 06 0p CS FF Smart ATW (high color saturation compensation) ON/OFF (OFF: 0 [Initial value], ON: 1) (Note 7)
*This mode is valid when WB mode is set to ATW.
MWB Red + A0 04 0B CS FF
MWB Red - A0 04 0C CS
FF
MWB Red Preset A0 04 0F CS FF Returns MWB red component settings to factory defaults (Initial value: 64)
MWB Red Direct A0 04 13 0p 0q CS FF pq: Direct MWB red components 0-255
MWB Blue + A0 04 15 CS FF
MWB Blue - A0 04 16 CS FF
MWB Blue Preset A0 04 19 CS FF Returns MWB blue component settings to factory defaults (Initial value: 64)
MWB Blue Direct A0 04 1D 0p 0q CS FF pq: Direct MWB blue components 0-255
ATW Masking OFF A0 04 28 CS FF Mask settings ON/OFF during ATW
ATW Masking ON A0 04 29 CS FF
ATW Mask Area Clr A0 04 2D CS FF Initialization of mask settings during ATW
ATW Mask Area Set A0 04 31 0p 0q 0r 0s 0t 0u Mask area settings during ATW (Note 1)
0v 0w 0x 0y 0z 0n CS FF
Iris Auto IRIS A0 05 00 CS FF
Manual IRIS (EI OFF) A0 05 01 CS FF
Manual IRIS (EI ON) A0 05 02 CS FF
Iris Level + A0 05 0B CS FF
Iris level operation during auto iris
Iris Level - A0 05 0C CS FF
Iris Level Preset A0 05 0F CS FF Returns iris levels during auto iris to factory defaults (Initial value: 40)
Iris Level Direct A0 05 13 0p 0q CS FF pq: Iris level 0 (Dark) - 100 (Bright) during auto iris (Initial value: 40)
Manual Iris Stop + A0 05 15 CS FF
Aperture operation during manual iris (Initial value: 17)
Manual Iris Stop - A0 05 16 CS FF
Manual Iris Stop Preset A0 05 19 CS FF Returns aperture during manual iris to factory default (Initial value: 17)
Manual Iris Stop Direct A0 05 1D 0p CS FF p: Aperture 1 (Close) - 17 (Open) during manual iris
*1: Only MD400 CS: Checksum
*2: Only MD300 FF: Terminator
Model: VCC-MD400/300