Sekonic L-758D Digital Camera User Manual


 
-22-
Reference:
It is possible to switch the shutter speed between full, 1/2 and 1/3 stops by custom setting
(See page 40).
The shutter speed can be set from 30 minutes to 1/1000 of a second. After 1/1000 sec, the
meter can be set at the following intermediate speeds: 1/75, 1/80,1/90, 1/100, 1/200, or
1/400.
If the ISO sensitivity is changed after the measurement is taken, the new converted
measured value (f stop value) will be displayed.
After measurement, the F stop value corresponding to the shutter speed is displayed
when the shutter speed is changed with Jog Wheel.
Readings outside the display range or beyond the measuring range are similar to the
previous instruction (see page 16).
You can select aperture scale or EV scale by holding Mode button and pressing AVE. /
EV.
5. Measurement
CAUTION:
There is danger of electric shock if the meter is handled with wet hands, during rain, in
areas splashed by water or where there is a lot of moisture. Under such conditions, it is
recommended that you use the meter in the cordless flash mode or Wireless flash radio
triggering mode, and keep the Synchro terminal cap in place.
NOTE:
The electronic flash unit may trigger when you connect the Synchro cord or operate the
Power button.
Triggering voltage is 2.0 to 400 volts. Below 2.0V, trigger flash with the cordless flash
mode (see page 22) or wireless flash radio triggering mode (see page 28), not with
synchro cord.
If you measure flashbulb, be sure to cheek the synchronized range and set the proper
shutter speed.
2-2 Auto-reset cordless flash mode
Measurements are made by the meter receiving the light from the flash. This measurement
mode is used when the Synchro cord will not reach because of the distance between the flash
and meter or when use of the Synchro cord is inconvenient.
1. Hold down the Mode button and turn the Jog
wheel to set Auto-reset Cordless Flash mode
.
2. Turn the Jog wheel to set shutter speed. When
setting shutter speed, first check the settings to
confirm that they correspond to the settings
available on the camera (camera flash
synchronization).
WARNING:
To avoid a danger of choking, please place Synchro terminal cap in a location where an
infant cannot reach and accidentally swallow it.