Sony XCD-SX910CR, XCD-X710CR, XCD-SX910UV, XCD-SX910, XCD-SX710 Digital Camera User Manual


 
17
Control
XCD-SX910CR/X710CR
XCD-SX910UV
XCD-SX910/X710
For offset address 444h, the length of the
UnitDependentInfo is 3 Quadlets.
CommandRegsBase is the base address of the camera
control register.
F0000000h + 3c0000h * 4 = F0F00000h
For offset address 454h, the length of the
VendorNameLeaf is 3 Quadlets. The subsequent 8
bytes are fixed at 00. After that, the four characters for
“SONY” are entered.
For offset address 464h, the length of the
ModelNameLeaf is 6 Quadlets. The subsequent 8 bytes
are fixed at 00.
For the XCD-SX910CR/SX910UV/SX910, the 16
characters “XCD-SX910 v1.00A” come next. For the
XCD-X710CR/X710, the15 characters are “XCD-
X710 v1.00A”.
Model names are subject to change with the upgrade of
firmwares.
Offset 0-7 8-15 16-23 24-31
Unit 444h 0003 CRC
Dependent 448h 40 3C 00 00 CommandRegsBase
Info 44ch 81 00 00 02 VendorNameLeaf
450h 82 00 00 05 ModelNameLeaf
VendorNameLeaf
Offset 0-7 8-15 16-23 24-31
Vendor 454h 0003 CRC
Name 448h 00 00 00 00
Leaf 44ch 00 00 00 00
450h 53 4F 4E 59 “SONY”
ModelNameLeaf
Offset 0-7 8-15 16-23 24-31
Model 464h 0006 CRC
Name 468h 00 00 00 00
Leaf 46ch 00 00 00 00
470h 58 43 44 2D “XCD-”
474h 53 58 39 31 “SX91”
478h 30 20 76 31 “0 v1”
47Ch 2E 30 30 41 “.00A”
The offset address of VendorNameLeaf is required to
be
44Ch + 000002h * 4 = 454h
The offset address of ModelNameLeaf is required to
be
450h + 000005h * 4 = 464h