ELECTRONIC SHUTTER
External trigger shutter
These modes are used to capture one image (one field) per trigger pulse.
Set DIP switches 6, 7, and 8 on the rear panel to mode 1 or 2. (Refer to the table below.)
When the trigger pulse width is 1/3 sec or more, the output signal is switched to a normal video signal.
There are two modes for timing in which a video signal is obtained.
Mode 1 (Non-reset mode)
In this mode, a video signal synchronized with a VD signal is output after a trigger pulse is input.
A video signal is synchronized with the external VD signal when an external HD/VD signal is input.
A video signal is synchronized with an internal VD signal when no external HD/VD signal is input.
Mode 2 (Reset mode)
In this mode, an internal video signal is output from a trigger pulse after a certain period of time.
Video sync is always fixed with odd field for XC-ST70 and even field for XC-ST70CE.
*
For more details of each timing chart, refer to pages 16 to 23.
Setting of external trigger shutter speed
There are two ways to set the shutter speed.
Using DIP switch on the rear panel
1
0
1
1
1
0
0
0
0
1
1
0
1
0
0
0
1
1
1
1
0
0
0
1
1
0
0
1
0
0
1
1
1
0
1
0
0
1
1
0
1
1
0
0
1
1
1
1
1
0
0
1
1
Mode 1 (Non-reset mode)
1
0
0
1
1
0
0
0
0
0
1
0
1
0
0
0
0
1
1
1
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
1
0
0
0
1
1
1
1
0
6
0
0
1
Switch
1
2
3
4
5
6
7
8
9
0
*
1/100
*
1/100
1/125 1/250 1/500 1/1000 1/2000 1/4000
**
1/10000
Frame: 0 / Field: 1
Mode 2 (Reset mode)
Switch
1
2
3
4
5
6
7
8
9
0
1/125 1/250 1/500 1/1000 1/2000 1/4000
**
1/10000
Frame: 0 / Field: 1
*
The external trigger shutter speed is set to
1/100 sec for XC-ES50/ES30,
XC-EI50/EI30 (EIA) and 1/120 sec for
XC-ES50CE/ES30CE,
XC-EI50CE/EI30CE (CCIR).
**
The external trigger shutter speed is
set to 1/10000 sec for XC-ES50/ES30,
XC-EI50/EI30 (EIA) and 1/8000 sec for
XC-ES50CE/ES30CE,
XC-EI50CE/EI30CE (CCIR).
1: ON
0: OFF
–: Any