Sony XC-ES50/50CE Digital Camera User Manual


 
29
XC-E series
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2 (RESET MODE)
For setting the shutter speed using DIP switch
*
1: This is a signal input from the outside. The trigger interval should be shutter speed (DIP switch) + 1 field
+ 2H period or more. The trigger interval shorter than described above cannot be ensured. If a trigger
pulse is not input under the prescribed conditions, the normal operation is engaged several V after a
change in input operation under the prescribed conditions.
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During
the trigger inhibit period, an input trigger may be missed.
*
4: After a period set by a DIP switch from the rising edge of the trigger, an image is output.
External trigger shutter operation
*
3
Normal operation
*
3
Trigger
Mode transition state
External input
inhibition area
(50 ms)
External trigger
shutter operation
*
2
Exposure time Te
*
4
T
*
4
T
*
2
Exposure
time Te
1 2
1 2
*
1
Trigger
Video out
WEN
250H
(XC-ES50/ES30,
XC-EI50/EI30)
293H
(XC-ES50CE/ES30CE,
XC-EI50CE/EI30CE
)
250H
(XC-ES50/ES30,
XC-EI50/EI30)
293H
(XC-ES50CE/ES30CE,
XC-EI50CE/EI30CE
)