Sony XC-ES50/50CE Digital Camera User Manual


 
22
XC-E series
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1
(NON-RESET MODE)
For setting the shutter speed using TRG width
HD/VD input
Continuous HD/VD input
*
1: This is a signal input from the outside. Be sure to input both HD and VD signals in this case.
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ES50/ES30, XC-EI50/EI30),
Te = Trigger width + 120 µs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)
(The trigger width should be between 2 µs and 1/4 s)
*
3: The normal operation state is engaged when the trigger high period exceeds 1/3sec. The external trigger
shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling
edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area. During
the trigger inhibit period, an input trigger may be missed.
*
4: In all cases the WEN signal indicates when a valid image is available. Normally, an image is output after
the external falling edge. If the falling edge of the trigger is very close to the falling edge of the external VD,
there may be a delay of 1VD in the output. The period of uncertainty is when the falling edge of VD is
between 65 µs before or 10 µs after the falling edge of the trigger.
*
5: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is
output.
Note
: An image is superimposed when the next exposure ends before the previous image is output.
*
1
Trigger
*
1
External HD
*
1
External VD
(
Continuous
VD)
EXT-VD
Video out
WEN
TRG
EXT-VD
EXT-VD
External trigger shutter operation
*
2
Exposure time Te
*
2
Exposure
time Te
*
3
Normal operation
*
3
Trigger
Mode transition state
External input
inhibition area
(50 ms)
External trigger
shutter operation
10 µs or more
*
2
Exposure time Te
–65 µs
65 µs
10 µs
+10 µs
*
4
T : T = Under –65 µs to +10 µs
1 2 3
1 2 3
*
4
T : T = Under –65 us to +10 µs
250H (XC-ES50/ES30, XC-EI50/EI30)
293H (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)
*
5