Toshiba CSGV90CC3 Security Camera User Manual


 
D4153660A
10
9. Troubleshooting
If any trouble occurs in use, check the following first. If the trouble persists, contact your distributor or our sales
representatives.
* When user confirms the troubles, please confirms the troubles on the condition that user connected the camera
system on the smallest composition and set 1500 byte / packet to the GVSP_SIZE (SCPSx) register for
making cause of trouble clear. About the connection of the smallest constitution, please refer to 6.Connection.
Phenomena Check item
Cannot turn on power - Check the connection of the Camera cable.
- Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.
Shooting image is not displayed - Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the ACT LED(LED1) is lighting or blinking.
- Check that the camera register settings are correct.
- Check that the lens aperture is not closed.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.
Frame drop occurs on shooting
image
- If some boards are installed in the PCI slots, remove the other
boards.
Shooting image remains still - Check that the camera is not in the random trigger mode.
- Check that the ACT LED(LED1) is lighting or blinking.
Cannot control camera from PC - Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.