Toshiba IK-629A Digital Camera User Manual


 
1-3
Power plugs of connected equipment must be disconnected before installations.
A 75-ohm coaxial cable (3C-2V or 5C-2V) is required for standard connection.
For details of wiring and operation of equipment to be connected, refer to their
operation manuals.
Lenses, coaxial cables for video signals and the power cord are not supplied
with the camera.
Notes on connecting
1. Basic connection Single system configuration
4. CONNECTIONS AND OPERATIONS
MONITOR TV
24V AC UL Listed Class 2 power supply / 12V DC power supply
AES
AC 24V ~ GND
LEVEL
VIDEO
VIDEO OUT
DC
H
L
DC 12V ...
V PHASE
CAMERA
AC 120V
minimum wire size of 18 AWG is recommended.
CAUTION : Never input 24V AC and 12V DC at the same time.
( ) POWER CORD (twisted pair line)
Since this camera uses 24V AC UL Listed Class 2 power supply or 12V DC
power supply, it should be connected to a power supply that allows for at
least 5w consumption.
Do not overload power supply
Line - Lock control
The camera is synchronized to the power frequency of 60 1 Hz covering
a normal fluctuation of the power frequency. However, the camera may not
cover a large fluctuation caused from the power generated by an engine
generator, etc.
It takes about 10 seconds or more until a stable synchronization is obtained
after the power is turned on. This is normal, because several seconds are
required to stabilize the camera against power noise.
Refer to "9. LINE-LOCK PHASE" for adjustment.
Cautions :
Matching the vertical synchronization with the power frequency is called
the Line-Lock.
This function is activated when the LINE LOCK switch is set to ON.
When two or more cameras are switched by the video switcher for viewing
by a monitor TV, the vertical sync. phase can be locked with the power
frequency, and a stable vertical sync. is obtained without being disturbed
at the time of switching.
MONITOR TV
Recorder Ready
Recorder Ready
VIDEO SWITCHER
TO 24V AC UL Listed
Class 2 power supply
CAMERA1
CAMERA2
(1) Mount a lens on the camera and connect equipment. Applicable lenses
are specified in Section 5 "LENS"
(2) Adjust the lens diaphragm and focus for optimum image.
2. Operation
ON
OFF
LINE LOCK
O
N
12
3
4