(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First set the "" to MODE and select E. TRG, then set the "" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
(a) Changing the polarity of inputting trigger pulse setting
1
Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either
, by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1
Set the "" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
1
Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
-- SHUTTER --
MODE E.TRG
E.TRG 1P SNR
TRG.P
EXP. 16ms
PART OFF
<MODE = E.TRG E.TRG = 1P SNR>
E.TRG mode
Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
1P SNR, 1P SR, PW SNR, PW SR, RR
0.01 ms 0.02 ms 0.4 ms 1 ms 16 ms
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
Exposure time setting at 1P SNR and 1P SR
Shutter mode MANU, SS, E.TRG
Input trigger pulse : negative polarity
Move up down
By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN