14
(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
(a) Changing the polarity of inputting trigger pulse setting
1
Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either
, by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1
Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
1
Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.
-- SHUTTER --
MODE E.TRG
E.TRG 1P SNR
TRG.P
EXP. 16ms
PART OFF
<MODE = E.TRG E.TRG = 1P SNR>
• E.TRG mode
• Partial scanning switch
OFF/60fps/90fps/E.60fps/E.90fps
1P SNR, 1P SR, PW SNR, PW SR, RR
0.01 ms 0.02 ms 0.4 ms 1 ms 16 ms
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
• Exposure time setting at 1P SNR and 1P SR
• Shutter mode MANU, SS, E.TRG
Input trigger pulse : negative polarity
Move up down
By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN