Telnet workstations require an RJ-45 Ethernet port or an RS-232 serial port and an operating system with a
Telnet client.
Switch power requirements
Power requirements are 1 Amp at 100 VAC or 0.5 A at 240 VAC.
Environmental conditions
Consider the factors that affect the climate in your facility such as equipment heat dissipation and
ventilation. The switch requires the following operating conditions:
Operating temperature range: 5°–40°C (41°–104°F)
Relative humidity: 10–90%, non-condensing
Installing a switch
Unpack the switch and accessories. The SN6000 Fibre Channel Switch product is shipped with the
following components
One Read-Me-First document
One End User License Agreement (EULA)
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Rack-Mount Kit Quick Start Installation
Instructions
HP StorageWorks SN6000 Fibre Channel Switch Quick Start Installation Instructions
One HP StorageWorks SN6000 Fibre Channel Switch
One HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Rack-Mount Kit
One or two standard power cords (depending on the switch model)
One or two HP Power Distribution Unit (PDU) power cables (depending on the switch model)
One serial cable
Four adhesive rubber feet
For the latest product information, including firmware, documentation, and supported SAN configurations,
see the following HP website: http://www.hp.com/go/SN6000
.
Table 7 Workstation requirements for QuickTools
Operating systems Windows 2003 and XP SP1/SP2
Red Hat Enterprise Linux 4, 5
SUSE Linux Enterprise Server 9 and 10
Memory 512 MB
Processor 2 GHz or faster
Internet Browser Microsoft Internet Explorer 6.0 or later
Netscape Navigator 6.0 and later
Mozilla 1.5 and later
Firefox 1.5 and later
Java Runtime Environment 1.4.2 or later
1
1. You must disable caching of temporary files and applets in Java to prevent conflicts with past or future versions of
QuickTools. Furthermore, you may need to disable caching again after upgrading Java.
Hardware RJ-45 Ethernet port