ROUTINE MAINTENANCE
• Check weld cables, control cables and gas hoses
for cuts.
• Clean and tighten all weld terminals.
PERIODIC MAINTENANCE
• Clean drive rolls and inner wire guide and replace if
worn.
• Blow out or vacuum the inside of the feeder.
CALIBRATION SPECIFICATION
All calibrations are factory set on the POWER FEED™
25M.
To verify the wire feed speed:
• Assemble a .045 (1.2mm) drive roll kit into the
POWER FEED™ 25M.
• Load a spool of .045 (1.2mm) electrode and thread
the electrode through the wire drive.
• Adjust the wire feed speed to 300 in/min
(7.62m/min).
• Press the COLD FEED switch and measure the
actual wire feed speed with a calibrated wire feed
speed tachometer.
• The measured wire feed speed should be within 2%
of the set value.
To verify the voltage display:
• Set the welding power source and POWER FEED™
25M to a CV procedure that gives steady "spray"
transfer in the arc.
• While a weld is being made, measure the voltage
from the feed plate to work with a calibrated volt
meter.
• The displayed voltage on the POWER FEED™ 25M
should be within 2% of the measured value.