Avanti K-600HW Security Camera User Manual


 
4 Engineer Programming
Once the engineers access code (9999) has been entered
from within DAY mode, the Day LED will be extinguished,
and all 8 Zone LED’s will flash to prompt for the selection
of the menu setting to be changed.
The following is a list of configurable menus available
within the engineers menu.
Press 1 to Set up the Programs.
Press 2 to Set up Zone Attributes.
Press 3 to Set up the Exit timer.
Press 4 to Set up the Entry timer.
Press 5 to Set up Bell Active time.
Press 6 to Set up Bell Delay time.
Press 7 to Set up Access codes.
Press 8 to Set up the Service Timer.
Press 9 to Enter the Test Menu.
Press 0 to Set up the System Flags.
Press Z to Exit back to DAY mode.
Press * twice within 2 sec’s for Factory Reset.
Press
to View the Event Log.
FACTORY DEFAULTS
Once a change has been made you need to accept or
abort the changes. Pressing Key A accepts the change
and returns you to the main engineer menu. Pressing Key
B aborts the change and returns you to the main
engineer menu. Within some menus Pressing A or B will
only return you to the top of that menu and Key Z needs
to be selected to return to engineers menu (this is
identified throughout programming guide).
4.1 Setting Up Programs.
Set-up Programs menu is entered from the Engineers
menu, by pressing Key 1.
When the Set-up Programs menu has been selected, Day,
PA and Tamper LED’s will flash to prompt the engineer to
select which of the 3 programs to set up.
Press A To Set program A.
Press B To Set program B.
Press * To Set program *.
Once the program that needs to be altered has been
selected, the following status LED’s will light.
DAY LED means Program A Selected.
PA LED means Program B Selected.
TAMPER LED means Program * Selected.
Zone Lights 1 to 4 will flash to prompt for a selection of
keys 1 to 4 to program the relevant program settings.
Press 1 To Set-up Immediate zones.
Press 2 To Set-up Timed Zones.
Press 3 To Set-up Time Inhibited zones.
Press 4 To Set-up the Exit Mode.
Press Z To return to Engineer Menu
4.1.1 Setting Up Immediate Zones
On entering Set-up Immediate Zones, the zones that are
currently set-up as immediate zones will have their
respective zone LED’s lit.
Pressing the key number that represents the zone to be
added or removed from the list of immediate zones will
toggle whether that zone is an immediate zone or not.
The zone LED will be lit if it is set as an immediate zone,
and extinguished if not.
Press A To Accept / B To Abort the changes.
4.1.2 Setting Up Timed Zones
On entering Set-up Timed Zones, the zones that are
currently set-up as timed zones will have their respective
zone LED’s lit.
Whether a zone is a timed zone or not is carried out in the
same way as immediate zones, by pressing the key
number for the zone that needs to be toggled to become
a timed zone or not.
Press A To Accept / Press B To Abort the changes.
4.1.3 Setting Up Time Inhibited Zones
On entering Set-up Time Inhibited Zones, the zones that
are currently set-up as time inhibited zones will have their
respective zone LED’s lit.
Whether a zone is a time inhibited zone or not is carried
out in the same way as immediate zones, by pressing the
key number for the zone that needs to be toggled to
become a time inhibited zone or not.
Press A To Accept / Press B To Abort the changes.
4.1.4 Setting Up the Exit mode
On entering Set-up the Exit mode, zone LED’s 1, 2, 3, or
NONE will be lit. The function represented by the LED’s is
as follows:
LED 1 = Timed exit.
LED 2 = Final Door set.
LED 3 = Immediate/Silent set.
NO LEDS means this program is disabled.
Press 0 To Select no exit mode.
Press 1 To Select Timed exit mode.
Press 2 To select Final Door set mode.
Press 3 To select Immediate/Silent set mode.
Press Z To return to Engineer Menu.
Press A To Accept / Press B To Abort the changes.
Entry time 30 secs
Exit time 30 secs
Bell delay 0 secs
Bell time 14 mins
Flags
Bell follow off
PTS in
p
ut = PTS
Z1:
Omit enabled
Double knock disabled
Normally closed loop
Zone enabled
Not a fire zone
Chime zone
Not a doorbell
Program
Z1 Timed
Z2 Time inhibited
Z3-5 Immediate
Z6-7 not used
Exit mode: immediate
silent set
A
Program
Z1 Timed
Z2 Time inhibited
Z 3-7 Immediate
Exit mode: Timed
*
Z2,Z3,Z4,Z5,Z6,Z7:
Omit enabled
Double knock disabled
Normally closed loop
Zone enabled
Not a fire zone
Not a chime zone
Not a doorbell
Z8:
Omit enabled
Double knock disabled
Normally open loop
Zone enabled
Not a fire zone
Not a Chime zone
A
Doorbell
Program
Not initialised
B
1 User code 1 0123
2 User code 2 not used
3 User code 3 not used
4 User code 4 not used
5 Holiday code not used
6 Manager code 8888
7 Engineer code 9999