Axis Communications AXIS Q6045 Mk II PTZ Security Camera User Manual


 
AXIS Q6045 Mk II PTZ Dome Network Camera
Detectors
2. Choose Object size from the drop-down list. Set the size limits of the object that should be detected. The camera will
detect any object whose size falls in between the minimum (blue shape) and maximum (white shape) range.
3. Use the Sensitivity slidebar to dene how sensitive the detection should be. The lower sensitivity selected on the
Sensitivity bar, the greater difference in luminance is needed between the object and the background for the detector to
be activated.
See the online help for more information.
Observations
The Observations element appears when a preset is selected in the drop-down list.
Left to Right - The value shows the amount of objects detected moving from left to right or, if the virtual line is horizontal,
objects detected moving downwards.
Right to Left - The value shows the amount of objects detected moving from right to left or, if the virtual line is horizontal, objects
detected moving upwards.
Total - The value shows the total amount of objects crossing the virtual line in any direction.
Refresh - Click Refresh to get updated observation values. The values are not automatically updated.
Reset - Click Reset to reset the observation values.
Audio Detection
The Axis product can be congured to generate an alarm when audio rises above or falls below the threshold value. The threshold
value can be set in the range 0–100 where 0 is the most sensitive and 100 the least sensitive.
1. Go to Detectors > Audio Detection.
2. Set the audio alarm level and click Save.
3. Go to Events > Action Rules and set up an action rule, see Set Up Action Rules on page 41.
Note
A multi-connector cable (available from Axis) is required when connecting external audio equipment to the Axis product.
See Multi-Connector Cable (sold separately) on page 62.
Detected audio is indicated by colored peaks in the Activity indicator. An event is triggered when detected audio rises above or falls
below the threshold value, which is represented by the bar.
38