Axis Communications P5522 Security Camera User Manual


 
AXIS P5522 PTZ Dome Network Camera
Live View Cong
Browser Viewer Description
AMC
Recommended viewer in Internet Explorer (H.264/Motion JPEG)
QuickTime
H.264
Java applet
A slower imaging alternative to AMC. Requires one of the following installed
on the client:
JVM (J2SE) 1.4.2 or higher
JRE (J2SE) 5.0 or higher
Windows Internet Explorer
Still image Displays stil l images only. Click the Refresh button in your browser to view a
new image
Server Push
Recommended viewer for other browsers (Motion JPEG).
QuickTime
H.264
Java applet
A slower imaging alter native to Server Push (Motion JPEG only).
Other browsers
Still image Displays stil l images only. Click the Refresh button in your browser to view a
new image
For more information, please see the online help .
Viewer Settings
Options for the viewer are congured under Live View Cong > Viewer Settings.
•TheShow viewer toolbar option will display the AX IS Media Control (AMC) or the QuickTime viewer toolbar under the
video image in your browser.
H.264 decoder installation. The administrator can disable install
ation of the H.264 decoder included with AXIS Media
Control. This is used to prevent installation of unlicensed copies. Further decoder licenses can be purchased from your
Axis reseller.
•SelectShow crosshair in PTZ joystick mode to enable a cross that will indicate the center of the image in PTZ joystick mode.
•SelectUse PTZ joystick mode as default to enable joystick mode. The mode can be changed temporarily from the PTZ
control panel.
You can enable recording fro
m the Live View page. The recordings are saved to the location specied in the AMC Control
Panel. See A X IS Media Control (AMC), on page 11.
User Dened Links
To display user-dened links in the Live View pa ge , select the Show custom link option, give the link a name and then enter the URL
to link to. Wh
en dening a web link do not rem ove the 'http://' from the U RL address. Custom links can be used to run scripts or
activate external devices connected to the product, or they can link to a web page . Custom links dened as cgi links will run the
script in the background, in a hidden frame. Dening the link as a web link will open the link in a new window.
Outpu
t Buttons
An
output on the Axis product can be controlled directly from the Live View page, by enabling the display o f output buttons. To
display the output buttons in the Live View page, select the type of control to use for the port from the drop-down list under
Live View Cong > Output Buttons:
Pulse activates the output for a dened period of time. The pulse time can be set as short as 1/100 second, and as
long as 60 seconds
Active/Inactive displays two buttons (on/off). The output ports must rst be congured under System Options> Ports &
Devices > I/O Ports.SeeI/O Ports, on page 44.