Axis Communications Q1614-E Security Camera User Manual


 
AXIS Q1614-E Network Camera
Hardware Overview
Status LED Behavior and Buzzer Signal for Levelling Assistant
For information on the Function button used for levelling the camera, see Connectors and Buttons.
Color
Buzzer
Camera position
Fixed green
Continuous beep
Level
Flashing green Fast interval Almost level
Flashing orange Medium interval Not level
Flashing red
Slow interval
Far from level
Replace the Lens
It is possible to use optional lenses for the Axis product.
To replace the lens:
1. Disconnect the iris cable.
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
To change the iris conguration:
1. Go to Setup > Video and Audio > Camera Settings. Iris conguration shows the current congured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
To change the iris conguration for P-iris lenses not listed in the drop-down list:
1. Download the iris conguration le from www.axis.com
2. Go to Setup > Video and Audio > Camera Settings. Iris conguration shows the current congured iris type.
3. In Iris conguration: Click Edit.
4. Go to the Upload tab.
5. Click Browse and select the conguration le.
6. Click Upload. The installed iris lens should now be included in the Iris Selection drop-down list.
7. Select the installed iris lens from the drop-down list and click OK.
Note
If you select a DC iris conguration le for a P-iris lens, an error message will appear below the iris conguration type in the
Camera Settings page. For custom DC Iris lenses, select Generic DC Iris option.
There is no need to restart the product after changing the lens. However, the product must be restarted if you are
interchanging between a P-iris, DC-Iris or xed/manual iris lens. In order to set the focus and position the lens, the
product must be connected to the network.
11