Axis Communications Q6045 Security Camera User Manual


 
AXIS Q604 Series
I/O connector
1 2 3 4 5 6
DC power input AC power input
Specications
Operating Conditions
The Axis product is intended for indoor use.
Product
Classication
Temperature Humidity
AXIS Q6042
AXIS Q6044
AXIS Q6045
IEC 60721-4-3
Class 3K3, 3M3
IEC 60529 IP52
0 °C to 50 °C
(32 °F to 122 °F)
10–85% RH (non-condensing)
Power Consumption
NONO
NO
TICETICE
TICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to 100 W or a rated output current limited to 5 A. Axis
recommends using the supplied midspan.
Product PoE+
DC AC
AXIS Q6042
21.1 W
24–34 V DC, max. 17.4 W 20–24 V AC, max. 24.7 VA
AXIS Q6044
20.7 W
24–34 V DC, max. 17.9 W 20–24 V AC, max. 25.9 VA
AXIS Q6045
21.8 W
24–34 V DC, max. 17.8 W 20–24 V AC, max. 26.0 VA
17