Bosch Appliances AN Security Camera User Manual


 
FLEXIDOME 5000 AN Safety | en 7
Bosch Security Systems Installation Manual AM18-Q0648 | v1.0 | 2013.03
1.3 Connection in outdoor applications
1.3.1 Safety precautions
Coax grounding: If an outside cable system is connected to the
unit, ensure that the system is grounded.
U.S.A. models only: Section 810 of the National Electrical Code,
ANSI/NFPA No.70, provides information regarding proper
grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors,
location of discharge unit, connection to ground electrodes,
and requirements for the grounding electrode.
Power lines: An outdoor system should not be located in the
vicinity of overhead power lines, electrical lights, or power
circuits, or where it may contact such power lines or circuits.
When installing an outdoor system, extreme care should be
taken to keep from touching power lines or circuits, as this
contact may be fatal. U.S.A. models only - refer to the National
Electrical Code Article 820 regarding installation of CATV
systems.
12 VDC/24 VAC power source: This unit is intended to operate
with a limited power source, this power source must comply
with EN60950. User supplied wiring, from 12 VDC/24 VAC
supply to unit, must be in compliance with electrical codes
(Class 2 power levels). Do not ground the 12 VDC/24 VAC
supply at the terminals or at the unit's power supply terminals.
Connection: The unit has connection terminals on flying leads.
In wet or outdoor installations make use of the VDA-455SMB
accessory or use a field wiring box with Nema 4 or IP66
protection level or better. Make the connections inside the
water tight compartment. After connections are made ensure
that the watertight compartment is tightly closed and cables
and conduits are properly sealed to prevent ingress of water.