Install ID submenu
Defaults submenu
Camera Control Communication
This camera is equipped with a coaxial communications transceiver. In
combination with VP-CFGSFT, the camera can be adjusted from the head-
end side of the coaxial cable. All menus can be accessed remotely giving
full control of the camera. With this communication it is also possible to
disable the local keys on the camera.
To avoid loss of communication on an installed camera, the
COMMUNICATION ON/OFF selection is NOT available while using
remote control. This function can only be accessed with the camera
buttons.
Function Selection Description
CAMERA ID Enter a 16 character camera name string. Use
LEFT/RIGHT to change position in the string, use
UP/DOWN to select the character. Use SELECT
to exit the string edit screen.
ID POS OFF, TOP, BOT Select TOP to display the camera ID in the upper
left corner; select BOT for the lower left corner.
The ID string is not displayed when the OSD
menus are open.
EXIT Return to the INSTALL menu
Function Selection Description
ALL
DEFAULTS
Select to restore the factory defaults. A
confirmation screen appears. Allow 5 seconds for
the camera to optimize the picture after a mode
reset.
EXIT Return to Mode menu