Bosch Appliances NDN-932 Security Camera User Manual


 
24 en | Installation FLEXIDOME HD
AM18-Q0615 | v1.0 | 2012.10 Installation Manual Bosch Security Systems
5.3 Connections
5.3.1 Make the connections
The unit has connection terminals on flying leads. In wet or
outdoor installations make use of a field wiring box with
NEMA Type 4X or IP66 protection level or better. Make the
connections inside a water tight compartment. Isolate unused
power wires individually. After connections are made ensure
that the watertight compartment is tightly closed and cables
and conduits are properly sealed to prevent ingress of water.
Cable tree
Use the following table to identify the wires in the cable tree:
For connections use wires of at least the same thickness.
CAUTION!
Isolate unused power wires individually.
Check the type label on the rear of the camera module for the
correct power ratings.
Wire color AWG Signal
Red 26 +12 VDC / 24 VAC
Brown 26 -12 VDC / 24 VAC
Yellow / Green 24
Earth
Black / Orange 28 Alarm Out A
White / Orange 28 Alarm Out B
White / Violet 28 Ground (Alarm In + Data)
Orange / Violet 28 Alarm In 1
Violet 28 Alarm In 2
White 28 Audio In
(Shield) 28 Ground (Audio In)
Black 28 Audio Out
(Shield) 28 Ground (Audio Out)