Bosch Appliances X10 SN Security Camera User Manual


 
80 en | Configuration Using a Web Browser VideoJet X10 SN
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
SNMP
The VideoJet X10 SN supports the SNMP V2 (Simple Network Management Protocol) for
managing and monitoring network components, and can send SNMP messages (traps) to IP
addresses. The unit supports SNMP MIB II in the unified code. If you wish to send SNMP
traps, enter the IP addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the
VideoJet X10 SN does not send them automatically, but only replies to SNMP requests. If you
enter one or two SNMP host addresses, SNMP traps are sent automatically. Select Off to
deactivate the SNMP function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP traps
You can select which traps are to be sent.
1. Click Select. A list is opened.
2. Click the checkboxes to select the required traps. All the checked traps will be sent.
3. Click Set to accept the selection.
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication
must be activated here to allow communication with the unit. The RADIUS server must also
contain the corresponding data.
To configure the unit, you must connect the VideoJet X10 SN directly to a computer using a
network cable. This is because communication via the network is not enabled until the
Identity and Password parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the VideoJet X10 SN.
Password
Enter the password that is stored in the RADIUS server.
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.