57
Problem: Scan button cannot be selected
➤Solution 1: A scan cannot be performed if the scan area is set too small (less
than 64 x 64 pixels). Increase the size of the scan area
➤Solution 2: A scan cannot be performed unless a scan area is specified. Specify a
scan area
➤Solution 3: A scan cannot be performed if the required memory is larger than
the free memory. Change the resolution (➜ p. 19) or scan area
(➜ p. 30) until the required memory is lower
Problem: The “Insufficient Memory” error message appears when
scanning
➤Solution 1: Select the smallest possible area and rescan
➤Solution 2: Lower the resolution and magnification settings for the output
device to the lowest possible values (➜ p. 19)
➤Solution 3: Rescan after closing all the application programs other than the one
used to start Plug-in Module CS-U
➤Solution 4: Rescan after you have restarted the application program used to
start Plug-in Module CS-U
➤Solution 5: Quit the application program used to start Plug-in Module CS-U and
increase the memory allocated to it. Restart the computer before
rescanning. Please refer to the manual for the application program
for the correct method for increasing its memory allocation
➤Solution 6: Increase the amount of RAM as required
Problem: The [Image] menu [ColorSync] option cannot be used in
Plug-in Module CS-U
➤Solution: ColorSync is not recognized after Mac OS upgraded to Version 9
after Plug-in Module CS-U was installed onto Mac OS 8.5 or 8.6.
Reinstall Plug-in Module CS-U (➜ p. 6)