SETTINGS
Line phase adjustment
When using a camera switcher to connect 2 cameras or more to one
monitor, there may be a vertical roll of the images when switched. In
such a case, set as described below.
1 Set the SYNC switch to the L-L position.
2 Switch the display on the monitor from camera 1 to camera 2.
Adjust the LINE PHASE volume on camera 2 until the vertical roll
of the image stops.
If more than two cameras are used, please repeat this procedure
for all the cameras.
CAUTION:
If the vertical roll cannot be corrected by setting the LINE PHASE
volume on camera 2, try setting the LINE PHASE volume on camera
1. If it still cannot be corrected, please check that the polarity of the
power cords of all connected devices is correct.
White balance adjustment
Normally the WB (white balance) switch is set
to the A (automatic) position and the white
balance is adjusted automatically. If a manual
white balance adjustment is necessary, follow
the steps below.
Set the WB switch to the M (manual) position,
then adjust the color.
• Turn R (VR303) to set the red ratio and/or
B (VR302) to set the blue ratio.
LEVEL
DC
VIDEO
A. I.
LENS
LH
VR301
ON
OFF
ON
WB
A
M
BLC
EI
VR302
BR
VR303
SYNC
L-L
INT
C-BW
L
H
SYNC
L-L
INT
WB
A
M
VR302
BR
VR303
L53S4/US GB 1998, 10, 27
English 11