FujiFilm 16303014 Digital Camera User Manual


 
107
Troubleshooting
Troubleshooting
Power and Battery
Problem
Problem
Possible cause
Possible cause
Solution
Solution
Page
Page
Power
supply
The camera does
not turn on.
The batteries are exhausted. Insert fresh or fully-charged spare batteries. 9
The batteries are not in the correct orienta-
tion.
Re-insert the batteries in the correct orienta-
tion.
9
The battery-chamber cover is not latched. Latch the battery-chamber cover. 10
The AC power adapter and DC coupler are
not connected properly.
Make sure that the AC power adapter and DC
coupler are properly connected.
The camera has been left for an extended
period with no batteries inserted and the
AC power adapter/DC coupler unplugged.
After inserting the batteries or connecting the
AC power adapter/DC coupler, wait a few mo-
ments before turning the camera on.
The batteries run
down quickly.
The batteries are cold.
Warm the batteries by placing them in a pocket
or other warm place and re-insert them in the
camera immediately before taking a picture.
vi
There is dirt on the battery terminals. Clean the terminals with a soft, dry cloth.
ON is selected for MONITOR SUNLIGHT
MODE.
Select OFF to reduce the drain on the battery. 96
The camera is in M mode.
Select another shooting mode. 22
The batteries are new, have been left unused
for an extended period, or have been re-
charged without first being fully discharged
(rechargeable Ni-MH batteries only).
Discharge Ni-MH batteries using the
P
DISCHARGE
option and recharge them in a battery charger (sold
separately). If the batteries do not hold a charge af-
ter repeated discharging and recharging, they have
reached the end of their service life and must be
replaced.
102
u
CONTINUOUS is selected for
F
AF MODE.
Select a different focusing option. 80
The camera turns
off suddenly.
The batteries are exhausted. Insert fresh or fully-charged spare batteries. 9
The AC power adapter or DC coupler has
been disconnected.
Make sure that the AC power adapter and DC
coupler are properly connected.
Troubleshooting