Fujitsu RX600 S4 Security Camera User Manual


 
RX600 S4 Options Guide 41
8 Controllers in non-hot-plug PCI
slots
V CAUTION!
Make sure you observe the safety notes in the chapter “Safety instruc-
tions” on page 11ff.
The system board has three non-hot-plug PCIe slots (slots 5 through 7), each
with a bandwidth of 2 GB/s and a mounting length of max. 315 mm.
When replacing/installing non-hot-pluggable components, you must proceed as
follows:
Ê Exit all applications and shut down the server properly.
Ê If your operating system has not switched off the server, press the On/Off
button.
Ê Unplug the power plugs from the grounded power outlets.
8.1 Installing controllers
Ê Open the server as described in the chapter “Preparation” on page 17f.
Ê Please read the documentation supplied with the PCI board.
Ê Plug any necessary cables into the PCI board.
Ê Remove the slot cover of the relevant slot on the back of the server.
I Keep the slot cover. If you remove a board, you must reinstall the slot
cover to comply with EMC (electromagnetic compatibility) regulations
and to satisfy cooling requirements and fire protection measures.