Furuno DFF1 Security Camera User Manual


 
21
2.2 Wiring Optional 1 kW Transducer
To connect optional transducer 50B-6, 50B-6B, 50B-9B, 200B-5, 200B-5S, 50/200-1T
or 50/200-12M, the optional Matching Box MB-1100 is required.
Matching Box MB-1100
Fabrication of transducer cable
Fabricate the transducer cable as illustrated below to connect it to the Distribution Box.
Fabrication of transducer cable
Matching Box Kit (Type: MB-1100, Code No.: 000-041-353)
Name Type Code No. Qty Remarks
Matching Box MB-1100 000-041-000 1 Cable w/8P connector sup-
plied for connection to net-
work sounder
Crimp-on Lug FV1.25-3 Red 000-538-113 6
Cord Lock NC-1 000-516-650 1 For use with separate trans-
ducer
TO NETWORK SOUNDER
(Cable is fitted with
8P connector. 8P-10P
converter connector is
required.)
Shield
50B-6/6B
50B-9B
200B-5S
50kHz
200kHz
SHIELD
BLK
RED
BLK
RED
TB2
1
2
3
4
5
J2 J1
BLK
3
2
1
WHT
TB1
02P6168
Jumper block setting
J2: Full power output
J1: Reduced power output
(SHIELD)
(BLK)
(BLU)
(GRN)
(RED)
TB2
1
2
3
4
5
50/200-1T
or
50/200-12M
50K
200K
Common
Common
Crimp-on lug
FV1.25-3, Red
Clamp here.
Taping
Vinyl sheath
Vinyl tube
Shield