Syslog Level
Select the ATA to report the log level. Default is NONE. The level is one of DEBUG,
INFO, WARNING or ERROR. Syslog messages are sent based on the following
events:
1. product model/version on boot up (INFO level)
2. NAT related info (INFO level)
3. sent or received SIP message (DEBUG level)
4. SIP message summary (INFO level)
5. inbound and outbound calls (INFO level)
6. registration status change (INFO level)
7. negotiated codec (INFO level)
8. Ethernet link up (INFO level)
9. SLIC chip exception (WARNING and ERROR levels)
10. memory exception (ERROR level)
The Syslog uses USER facility. In addition to standard Syslog payload, it contains the
following components:
GS_LOG: [device MAC address][error code] error message
Here is an example: May 19 02:40:38 192.168.1.14 GS_LOG: [00:0b:82:00:a1:be][000]
Ethernet link is up
NTP server
URI or IP address of the NTP (Network Time Protocol) server, which will be used by the
phone to synchronize the date and time.
Enable Video
Surveillance
When set to Yes, GXW410x will start converting video feed received from analog
camera to IP packets. In order to view this video feed, please follow instructions given
under Video Surveillance chapter on page 23.
RTSP Port
By default it is 554.
Grandstream Networks, Inc. GXW-410x User Manual Page 18 of 37
Firmware 1.0.0.53 Updated: 04/2007