Harbor Freight Tools 95592 - 1 HP Camera Lens User Manual


 
SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 PAGE 10
INSPECTION, MAINTENANCE, AND CLEANING
WARNING! Always shut off the electrical power to the GFCI outlet rst. Then, dis-
connect the Pump’s Power Cord & Plug from the GFCI outlet prior to performing
any inspection, maintenance, or cleaning procedures.
Before each use,1. inspect the general condition of the Pump. Check for cracked
or broken parts, damaged electrical wiring, clogged Impeller Cover, Impeller, Dis-
charge Pipes, and any other condition that may affect safe operation. If abnormal
noise or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
Carefully set the Pump in place. 6. Do not lower or raise the Pump by the Power
Cord or Discharge Pipe. (See Figure E.)
The Float Switch (2) automatically switches on and off at a water depth of approxi-7.
mately 4 inches. The ON/OFF height can be manually changed by adjusting the
Float Switch Lock. CAUTION: Do not run the Pump dry. Doing so will increase
wear to the unit and possibly cause seal damage. (See Figure E.)
Note: This Pump has a built-in thermal protector for the Motor which automatically
shuts it off to avoid overheating. After the Motor cools, it will cycle back on. Wait
for the cycle to continue. Do not try to turn on the Pump manually after it has auto-
matically shut off.
Connect additional Discharge Pipe as needed to direct the water discharge to 8.
the desired location. The discharge should be kept as short as possible with a
minimum number of turns. IMPORTANT: Do not exceed the maximum lift of the
Pump:
Model 95591 = 20 Feet.
Model 95592 = 24 Feet.
Model 95593 = 26 Feet.
Connect the Power Cord & Plug to its 115 volt, GFCI electrical outlet, while making 9.
sure to form a “drip loop” in the Power Cord. (See Drip Loop, page 5.)
When the water level exceeds approximately 4 inches the Pump will automatically 10.
turn on and run continuously until the water level falls below 4 inches at which time
the Pump will automatically turn off.
11. WARNING! When shutting off power to the Pump, always shut off the electrical
power to the GFCI outlet rst. Then, disconnect the Pump’s Power Cord & Plug
from the GFCI outlet.