Harbor Freight Tools 95592 - 1 HP Camera Lens User Manual


 
SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 PAGE 9
TO 115 VOLT, GROUNDED
GFCI OUTLET
1/8”
AIR BLEED HOLE
BASE
(25)
DISCHARGE PIPE
(NOT INCLUDED)
CHECK VALVE
OR
UNION
(NOT INCLUDED)
FIGURE E
o
1-1/4” OR 1-1/2” NPT PVC
3. Connect the Discharge Pipe to the Base (25). NOTE: Make sure the Discharge
Pipe is secured to a solid surface, with appropriate hardware (not included), to
ensure the stability of the Pump. (See Figure E.)
Install an additional union (not included) or other means of separating the Dis-4.
charge Pipe just above the oor to facilitate removal of the Pump if necessary.
(See Figure E.)
A check valve (not included) is recommended just above, or in place of, the union 5.
to prevent the backow of water after each pump cycle. If a Check Valve is used,
a 1/8” diameter air bleed hole should be drilled through the Discharge Pipe just
above the lower Base (25) to prevent Pump “airlock”. A small spray of water out of
this hole is normal while the Pump is running. (See Figure E.)