Hitachi kp-hd20a Digital Camera User Manual


 
1) Press the Set button for at least 2 seconds to display the
Main menu on the monitor screen.
2) Check the current settings at the main menu.
3) Shift the cursor vertically by pushing the Up and Down
buttons, then press the Set button to change the setting of
the selected item.
4) To return to the normal screen, press the Set button.
5) Changed settings are stored in the camera memory (flash
memory) and restore them when the power is switched on.
6) When button operation is not performed for 1 minute during
displaying menu, changed items are saved and menu display
disappears.
MAIN MENU
……Seting scene files setting
……Shutter speed setting
……Light control menu
……AGC setting menu
……White balance setting menu
……Sub menu
……Camera title setting menu
……Lens setting menu
……Camera tilte setting menu
SHUTTER SPEED
1) Shutter speed can be switched at MAIN MENU. Select
"SHUTTER" by Up (Down) button. Then shutter speed can
be changed by Right/Left button.
[Preset]
1/30(1/25) 1/50 1/100 1/250 1/500 1/1000
1/20001/50001/100001/20000 1/50000
AESAES&LENS(1/1000)AES&LENS(1/2000)
AES&LENS(1/5000)
Factory setting is “1/30”.
* AES&LENS is AES priority mode.
Scene file setting
Scene file is a function to record various mode settings and the
adjusted values of the camera at the file.
1) Press the Set button for at least 2 seconds to display the
main menu on the monitor screen.
2) Use UP and Down buttons to move the cursor to MAIN
MENU. push the Right and Left button to change the scene
file.
FILE1<->FILE2<-> FILE3<->FILE4<->FILE5<->FILE1
Factory setting is FILE1.
Main menu
LIGHT CONT MENU
Light control menu
……Exposure control mode
……Video level adjustment
……Automatic level conrol gate setting
……WDR function setting
……WDR brend ratio setting
……WDR short exposure shutter setting
……WDR short exposure convergence
level setting
Light control menu setting
1) Press the Set button for longer than 2 seconds to display
the Main menu.
Select “LIGHT CONTROL” by Up (Down) button. Then LIGHT
CONTROL MENU can be displayed by Rght,
(1) PEAK/AVE(PEAK/AVERAGE)
Set the rate of automatic iris PEAK/AVERAGE.
0/100, 15/85, 30/70, 50/50, 75/25, 100/0.
(2)LEVELLEVEL
Standard level of Automatic exdposure control( AUTO IRIS,
AGC, AES ) (dark)-128 to 0 to127bright
(3)ALC GATEPEAK/AVERAGE
Set PEAK/AVERAGE Automatic level control gate.
OFF:Full screen Select 1 to 9.
(4) WDR MODEWide dynamic range mode
Set WDR.
OFF/ONmanual/AUTO
(5) WDR BLENDWDR short/long exposure ratio
Set WDR short/long exposure ratio.
12850%to 255100%
Effective only at the time of WDR ON
(6) WDR SHUTTTER(WDR short exposure shutter speed)
Set the shutter speed of short exposure at the time of WDR
manual mode. Long exposure is set by SHUTTER
command.
(7) WDR LEVELShort exposure shutter desired value o
f
AUTO
Short exposure convergence level setting of short exposure
shutter automatic control
095%to 255110%
Effective only at the time of WDR Auto mode
7