KY-F550 Random Trigger System
Trigger signal
Charges accumu-
(a)
lated in the CCD
Sync non-reset mode (a) (a) (b) (b)
Image output signal
SI output signal
(b)
(b)
(a)
For verifying the image of an object detected.
If the trigger signal for the object detected is input, charges will be output
following the next SYNC signal while simultaneously, the SI signal will be
output as well, hence allowing the images to be stored in the me mory.
The method of SYNC non-reset mode allows camera timing to be output