JVC LST0886-001A Security Camera User Manual


 
37
(TV) is applicable to VN-V series only. (TX) is applicable to VN-X series only.
B FTP (continued) Time Filter:
For specifying the periodic FTP transfer action with respect to each day of
the week and setting the corresponding time of the day.
Applicable day of week : Sunday, Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday
Alarm action
Unmask Span : For specifying the time period for invoking the
action
Mask Span : For specifying the time period to stop the action
Unmask All : Activated at all times
Mask All : Stopped at all times
Applicable time period : For specifying the start and end time in hours and
minutes.
Pre-/Post-recording parameter:
[PrePostRecording Frame Rate] : For specifying the JPEG frame rate for
FTP pre-/post-recording.
[
Set values
: 1 fps, 2 fps, 3 fps,
5 fps,
6 fps, 7.5 fps, 10 fps,
15 fps, 30 fps (
T
V)]
[PrePostRecording Before Trigger] : For setting the FTP pre-recording
trigger time (recording time before
alarm input) in seconds.
[Setting range: 0 to 60 seconds]
[PrePostRecording After Trigger] : For setting the FTP post-recording
trigger time (recording time after alarm
input) in seconds.
[Setting range: 0 to 60 seconds]
The maximum time intervals for [PrePostRecording Before Trigger] and
[PrePostRecording After Trigger] are determined by the JPEG size on the
Encoding page as well as the set values for [PrePostRecording Frame Rate].
A message appears if the combination of the entered values are not feasible.
C Alarm Output For setting the alarm output.
Duration For setting the output time of [Manual Output].
[Setting range : 0, 100 msec to 5000 msec]
Manual
Output
For operating alarm output manually.
The current output status appears on the right. When [Duration] is set to “0”,
pressing the [Make] button switches the alarm to Make output, while
pressing the [Break] button switches the alarm to Break output.
When [Duration] is set to a value other than “0”, pressing the [Make] button
switches the alarm to Make output only during the duration of the output,
upon which it switches to Break output.
When the output duration is set to a value other than “0”, pressing the
[Break] button switches the alarm to Break output only during the duration of
the output, upon which it switches to Make output.