JVC TK-C1530E Security Camera User Manual


 
24
Setup
Connecting alarm input/output terminal
Alarm input terminal
Connect infrared sensor, door sensor, metal sensor or sensor of manual
switch and the like.
To prevent noise from entering the internal circuit, supply non-voltage
setting signal.
Do not supply voltage.
Can be set via menu whether to set to alarm when the contact is short
(MAKE), or when the contact is open (BREAK). (A Pg. 39)
Supply such that the alarm signal continues for more than 200 ms. The
recognition of alarm signal may not be guaranteed if less than 200 ms.
Alarm output terminal
Connect to alarm devices such as alarm, indicator, light or buzzer.
As it is an open type collector output insulated by photocoupler, it will turn
on during alarm.
This terminal has polarity. Make sure to connect such as the voltage of +
terminal is higher than - terminal. It will be damaged if reverse voltage is
supplied.
Connecting the back panel (continued)
CLASS 2 ONLY(U TYPE)
ISOLATED POWER ONLY(ETYPE)
SEE INSTRUCTION
MANUAL
POWER
VIDEO OUT
SELECTOR
SET
MENU
INT LL
ONRX TERM-OFF
+
1
2
DC12V d
AC24V H
IN
GND
OUT +
OUT -
22ǡ
25
When mounting the camera on a fixer, pan/tilt and the like, use the camera-
mounting screw hole located on the camera-mounting bracket.
Note:
Use a camera-mounting screw with a length shorter than 7 mm from the
camera-mounting face. Do not use a screw that is longer than the specified
length. It may damage the internal parts.
Mounting the camera
IRIS
VIDEO
DC
LEVEL
COLORVIDEOCAMERA
Camera-mounting
screw hole
Camera-mounting bracket fixing
screws (x2: M2.6 x 6 mm)
Rotation-preventive hole Camera-mounting bracket
7 mm
or