A SERVICE OF

logo

42
Extended Remote Jack
The play, FF, RWD keys can be added to the remote control
functions by using the equivalent circuit showing below.
Circuit diagram:
R1
1k
S1
4
REC PLAY REW MARK FFREC
PAUSE
S2 S3 S4 S5 S6
R2
3.9k
R3
6.8k
R4
11k
R5
15k
R6
30k
R8
220
R9
220
SKIP
BACK
S7
R7
470k
3
2
1
Notes:
•PlaybackduringclosingandholdingthePLAYswitch,andskipbackthen
pauseatthepointwhenitopened.
•TheMARKswitchisinvalidforthePMD620MKII.
•Resistanceerror-Within5%.
•Neverapplyexternalvoltage.Doingsowillresultinmalfunction.
•Insuratethecircuitsothatitcannotbetoucheddirectly.Useastructurethat
protectsthecircuitfromstaticelectricity,whichwillcausemalfunction.
•Donotoperatetheswitchesatthesametimeasthebuttonsontheset.
•D&Mprofessionalacceptsnoresponsibilitywhatsoeverforanydamagesor
infringementsofpatentsorotherrightsresultingfromtheuseofthecircuits.
ThisdoesnotsanctionpatentsorotherrightsofD&Mprofessionalorthird
parties.
•Itisstrictlyforbiddentoreprintorreproducethecircuitdiagramsinpartor
inwhole.
Plug Type (1/8” T-R-R-S Mini Plug)
ø3.5/4P (TMP-B66)
1
4
23
1: Tip
2: Ring
3: Ring
4: Sleeve