Microsoft 9.21 Photo Scanner User Manual


 
115
• Cannot specify Gray Scale with duplex document. (DS00011)
Cause: Duplex scanning is specified with Gray Scale specified.
R
esolution: At duplex scanning, select Black/white binary or Half tone for the
[Image type].
• Cannot specify Individual Setting with Gray Scale. (DS00012)
• Cannot specify Long Page Scan with Gray Scale. (DS00017)
Cause: Gray Scale and Individual Setting are specified at the same time.
Gray Scale and Long Page Scanning are specified at the same time.
R
esolution: Uncheck Individual Setting when specifying Gray Scale.
At Long Page scanning, select Black/white binary or Half tone for the
[Image type].
• Your application using may not support page end detection, or undefined image size
function. (DS41051)
Cause: Scanned image may not be displayed correctly when scanning by
using the “End of page detection” or “Automatic (Page) Size
detection” function with the application which is not supporting these
functions.
R
esolution: When scanned image is not displayed correctly, please select
“disable” for the [Option]-[Rotation]-[Automatic Size and Skew
detection].
• Dither pattern file not found. (DS00015)
Cause: File download has been specified, but a file has not been selected.
R
esolution: Use the [File…] button to specify a file.
• Gamma pattern file not found. (DS00014)
Cause: File download has been specified, but a file has not been selected.
R
esolution: Use the [File…] button to specify a file.
• Selected file can not be deleted. (DS31002)
Cause: If the selected setting file is write-protected, it cannot be deleted.
R
esolution: Use Explorer to delete the file later.