Operation displays (manual)
The operation displays appear at the bottom of the screen for 4 seconds
when any of the following operations have been performed with the
operation panel of the ROP
“MASTER GAIN” is changed
“SHUTTER” is changed
“LENS EXT” is changed
“FILTER” is changed
“SCENE FILE” is changed
“REF LOAD” is changed
The display time can be changed from “MAINTENANCE” menu → “PM
OPERATION STATUS” → “STATUS DISP TIME”
FILTER FIL1
Item Display
range
Remarks
MASTER GAIN Setting
values on
camera
The master gain value is displayed
here
(in 3 dB increments)
For the setting values, refer to the
Operating Instructions for the camera
SHUTTER Setting
values on
camera
The speed of the electronic shutter is
displayed here
For the setting values, refer to the
Operating Instructions for the camera
LENS EXT 10
20
The magnification of the lens extender
is displayed here
When the magnification of the
lens extender is set to 2×, “20” is
displayed
Otherwise, “10” is displayed
FILTER 4 characters The name of the ND filter is displayed
here
SCENE FILE SCENE1
SCENE4
OFF
This indicates the scene file name
REF LOAD FACTORY
USER1
USER2
USER3
This indicates the reference file that was
loaded using the SCENE command
Operation displays (AUTO)
If the AWB function, ABB function, or AUTO SETUP function has
been activated when a menu is not displayed on the picture monitor,
information on the operation performed appears at the bottom of the
screen
When the AUTO SETUP operations are displayed, they will remain
displayed until the operations are completed
The display is cleared 4 seconds after the operations are completed
If the operations cannot be completed, they will remain displayed until
the NG (error) items of the AUTO function are released
The display time can be changed from “MAINTENANCE” menu → “PM
OPERATION STATUS” → “STATUS DISP TIME”
AUTO SETUP: ACTIVE
GAMMA OPERATION
Item
Display description:
Appears on two lines at the bottom of the screen
Top line: status
Bottom line: Detailed information
ABB START ABB: ACTIVE
(None)
AWB START AWB: ACTIVE
(None)
AUTO OK
(Common to
ABB, AWB, and
AUTO SETUP)
ABB: OK AWB: OK AUTO SETUP: OK
(None)
AUTO NG1*
1
(Only for ABB
and AWB)
ABB: NG AWB: NG
Detailed information of the NG (error) message is
displayed here*
1
AUTO SETUP
START*
2
AUTO SETUP: ACTIVE
Detailed information is displayed here*
2
AUTO NG2*
3
(Only for AUTO
SETUP)
AUTO SETUP: NG
Detailed information of the NG (error) message is
displayed here*
3
AUTO BREAK
(Common to
ABB, AWB and
AUTO SETUP)
ABB: BREAK AWB: BREAK AUTO SETUP: BREAK
(None)
AUTO READY
(Only for AUTO
SETUP)
AUTO SETUP: READY
(None)