Panasonic AW-E300 Digital Camera User Manual


 
Synchro-scan
-
99.68 Hz
250.0 Hz
492.2 Hz
984.4 Hz
1.969 kHz
3.938 kHz
7.875 kHz
Shutter Speed
OFF
1/100
1/250
1/500
1/1 000
1/2 000
1/4 000
1/10 000
Required luminance ratio
1
2
4
8
16
32
64
160
-41-
#4 CCD Read Out Mode Setting [Field/Frame:
FIELD/FRAME 1/FRAME2]
FIELD: CCD storage will be by field storage.
FRAME 1: Vertical resolution increases in frame
storage.
FRAME 2: Vertical resolution is raised without
increasing residual images by frame storage
and 1/60-second shutter speed.
#5 Gain Up Setting [Gain: AGC HIGH/AGC LOW/
0 dB - 30 dB/NIGHT EYE]
AGC LOW: The Auto Gain Up control with a maxi-
mum gain increase of about 18 dB adjusts the
luminance automatically.
AGC HIGH: The Auto Gain Up control with a maxi-
mum gain increase of about 30 dB operates. If
the luminance is still insufficient, the Night Eye
(digital gain up) also adjusts the luminance
automatically.
0 dB: 0 dB should be selected in normal cases.
1 dB - 30 dB: Use this range if sufficient video out-
put cannot be obtained even when the lens iris
is opened in shooting dark scenes.
Night Eye: Sensitivity is increased by adding the
digital gain up to 30 dB.
POWER
OPERATE
BAR
CAM
MODE
GAIN AWC
SCENE
FILE
ABC
ATW
A
B
AUTO/AIW
ELC
LOW
MID
MANU
ON SC H
OFF
HIGH AGC
OFF
1 / 100
SHUTTER
ON
OFF
1
.
2
.
3
.
4
.
G/L PHASE
T.PED CABLE COMP
90° 180°
0° 270°
YC
Notes
Only 0 dB, 9 dB, or 18 dB, AGC LOW, AGC HIGH
can be selected in case of using the RCU (RCB).
If the lens iris switch is at MANUAL, when operat-
ing the camera alone or when the iris switch on the
RCU (RCB, Hyblid control panel) is at AUTO, AGC
may not function.
AGC HIGH when the AGC selection switch on the
hybrid control panel is at AGC.
0 dB when the manual gain switch on the hyblid
control panel is at LOW, 9 dB when it is at MID, or
18 dB when it is at HIGH.
Hybrid Control Panel
AGC
Manual GAIN