Cable Compensator AW-RC400
37 (E)
Parts and their function
;MONITOR1, 2 connectors
The video signals of the cameras selected by the
AW-RP400 pan/tilt head controller or the AW-CB400
remote operation panel which is connected to the
AW-RP400 are output from these connectors.
The output signals are cable-compensated signals of the
same type as the input signals. For instance, if a channel
to which composite signals have been input is selected,
these composite signals will be cable-compensated and
output.
<Y/VIDEO IN connectors [1 to 5]
The analogue video signals are input to these
connectors. They are terminated internally by a 75-ohm
resistance.
Either Y (component signals or Y of the Y/C signals with
sync) or VIDEO (composite) signals are supplied.
=Pr/C IN connectors [1 to 5]
The analogue video signals are input to these
connectors. They are terminated internally by a 75-ohm
resistance.
Either Pr (R-Y among the component signals) or C (C of
the Y/C signals) signals are supplied.
>Pb IN connectors [1 to 5]
The analogue video signals are input to these
connectors. They are terminated internally by a 75-ohm
resistance.
The Pb (B-Y among the component signals) signals are
supplied.
?Y/VIDEO OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Y or VIDEO (composite)
signals that are in accordance with the input signals are
output. Y signals are output if component Y signals have
been input to the Y/VIDEO IN connectors
[1 to 5], and composite signals are output if composite
signals have been input.
@Pr/C OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Pr or C signals that are
in accordance with the input signals are output.
Pr signals are output if Pr signals have been input to the
Pr/C IN connectors [1 to 5], and C signals are output if C
signals have been input.
APb OUT connectors [1 to 5]
The analogue video signals are output from these
connectors. Cable-compensated Pb signals are output if
Pb signals have been input to the Pb IN connectors
[1 to 5].
BAC adaptor storage space
The AC adaptor can be stored here when the ambient
temperature in the location where the cable compensator
has been installed is under 30°C. Remove the two
screws, and remove the storage space cover. Pull out the
AW-PS301 AC adaptor, and stow it away while ensuring
that the cable is not subjected to stress. Trouble will
occur in the AC adaptor if the ambient temperature
exceeds 30°C, in which case it should not be stored in
the space.