[Originating port number]
Select a port number to be used to receive the command alarm.
• Available range: 1-65535
• Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
11.2 Configure the settings relating to the camera
action on alarm occurrence [Alarm] (BL-VT164W/
BL-VT164)
Click the [Alarm] tab on the “Alarm” page. (®page 34, page 35)
The settings relating to the camera action at an alarm occurrence can be configured in this section. Refer to
pages 77, 80 and 82 for further information about the settings relating to the alarm, the alarm image and
the alarm output terminal.
Camera action on alarm
[Terminal alarm 1]
Select an action to be taken when a terminal alarm 1 is detected from the following.
• Off: Does not take any action even when a terminal alarm 1 is detected.
• 1-64: When the registered preset position is selected, the camera will move to the selected preset position
when a terminal alarm 1 is detected.
• Default: Off
[Terminal alarm 2]
Select an action to be taken when a terminal alarm 2 is detected from the following.
• Off: Does not take any action even when a terminal alarm 2 is detected.
• 1-64: When the registered preset position is selected, the camera will move to the selected preset position
when a terminal alarm 2 is detected.
• Default: Off
[Terminal alarm 3]
Select an action to be taken when a terminal alarm 3 is detected from the following.
• Off: Does not take any action even when a terminal alarm 3 is detected.
• 1-64: When the registered preset position is selected, the camera will move to the selected preset position
when a terminal alarm 3 is detected.
• Default: Off
Operating Instructions 79
11 Configure the alarm settings [Alarm]