Panasonic WV-CP500 Security Camera User Manual


 
18
External synchronization switch
The settings of the alarm input/output are configured on the SETUP menu.
Refer to the network operating instructions (PDF) for further information.
Important:
• Besuretoturnoffthepowerofeachdevicebeforeconnection.
Alarm output
Input specification: Open collector out-
put (max. voltage: 16 V DC)
Off: Internally pulled up
2 V to 4 V DC
On: Output voltage 1 V DC or less (max.
drive current: 100 mA)
Functions: Alarm output
Black-and-white switching output
Alarm input
Input specification: No-voltage make
contact input (3 to 5 V DC, internally
pulled up)
Off: Open or 3 to 5 V DC
On: Make contact with GND (required
drive current: 0.2 mA or more)
Functions: Alarm input
VMD enabling input
Color/BW switching input
Scene file switching input
* When an external device is connected, exercise care to avoid exceeding the rating.
* Applicable wire: 22 AWG-28 AWG, solid wire/stranded wire
Strip the end 9 mm to 10 mm {11/32" to 13/32"} of the wire and
insert it.
POWER
ALARM OUT
ALARM IN
GND
VIDEO OUT
120V ~ 60Hz
WV-CP500
9 mm - 10 mm
{11/32" to 13/32"}
ALARM OUT (Alarm output)
ALARM IN (Alarm input)
GND
The external terminal is the same between
WV-CP500 and WV-CP504.
Stripped
POWER
ALARM OUT
ALARM IN
GND
VIDEO OUT
120V ~ 60Hz
WV-CP500
9 mm - 10 mm
{11/32" to 13/32"}
ALARM OUT (Alarm output)
ALARM IN (Alarm input)
GND
The external terminal is the same between
WV-CP500 and WV-CP504.
Stripped