Panasonic WV-SP102 Security Camera User Manual


 
40
40
41
Configure the settings relating to the priority stream [System]
Click the [System] tab on the "User mng." page. (Pages13and14:Howtodisplay/operatethesetupmenu)
The description below is the configuration of the priority stream that can transmit images without deteriorating the
image quality and refresh interval even when multiple users access concurrently.
Priority stream
[Activation]
Select"On"or"Off"todeterminewhetherornottouse
the priority stream.
Default:Off
Note:
•When"On"isselectedfor"Activation"of"Priority
stream", number of users who can access the unit
may be limited.
[Destination IP address (1)]
Enter the first destination IP address.
[Destination IP address (2)]
Enter the second destination IP address.
[Stream type]
Select either "JPEG", "H.264(1)" or "H.264(2)".
JPEG: JPEG images will be transmitted.
H.264(1): H.264(1) images will be transmitted.
H.264(2): H.264(2) images will be transmitted.
Default: JPEG
[Refresh interval*]
Select the refresh interval from the following.
This setting is validated only when "JPEG" is selected
for "Stream type".
0.1fps/ 0.2fps/ 0.33fps/ 0.5fps/ 1fps/ 2fps/ 3fps/ 5fps/
6fps*/ 10fps*/ 12fps* (PAL model)/ 15fps*/ 30fps*
Default: 1fps
Note:
•When"On"isselectedfor"H.264transmission",the
refresh interval may be longer than the set value
when any value with an asterisk (*) on the right is
selected.
[Image capture size]
Select the image capture size from the following.
When"4:3"isselectedfor"Aspectratio"
QVGA/ VGA/ 1280x960*
1
When"16:9"isselectedfor"Aspectratio"
320x180/ 640x360/ 1280x720*
1
This setting is validated only when "JPEG" is selected
for "Stream type".
Default: 1280×960*
1
VGA*
2
*1
SP105
*2
SP102