Service Connector
An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and
adjustments. To use the cable, simply plug one end of the cable directly into the service connector of the
ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor.
To assemble a longer service cable for the ICS090 Series Camclo
sure, purchase the following parts at a
local electronics supply store:
Qty Description
1 2.5 mm monaural headphone plug
1 CPM 88 miniature coaxial connector
1 RG174/U coaxial cable
To assemble the cable:
1. Attach the CPM 88 miniature coaxial connector to one
end of the cable. Follow the directions
supplied with the miniature coaxial connector.
Figure 15. Attaching the 2.5 mm Monaural Headphone Plug
2. Attach the 2.5 mm monaural plug to the other end of the coaxial cable (refer to Figure 15):
a. Remove the support sleeve from the plug, and then
slip the support sleeve over the end of the
cable.
b. Prepare the cable.
c. Solder the center connector of the cable to the center pin of the plug.
d. Thread the braid of the cable through the hole in the crimp pin, and
then solder the braid to
the top of the crimp pin.
e. Crimp the end of the crimp pin around the cable.
f. Reassemble the support sleeve and the plug.
2.5 mm MONAURAL
HEADPHONE PLUG
CENTER CONDUCTOR
BRAID (SHIELD)
COAXIAL
CABLE