Pelco Manual C1471M (10/98) 7
Table B. Switch Settings for SW2 – P-Type Control
NOTE:
For Coaxitron
®
controls, all switches on SW2 MUST be OFF.
For D-type control systems, refer to Table C.
Receiver Address Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5
1 OFF OFF OFF OFF OFF
2ONOFF OFF OFF OFF
3 OFF ON OFF OFF OFF
4ONONOFF OFF OFF
5 OFF OFF ON OFF OFF
6ONOFF ON OFF OFF
7 OFF ON ON OFF OFF
8ONONONOFF OFF
9 OFF OFF OFF ON OFF
10 ON OFF OFF ON OFF
11 OFF ON OFF ON OFF
12 ON ON OFF ON OFF
13 OFF OFF ON ON OFF
14 ON OFF ON ON OFF
15 OFF ON ON ON OFF
16 ON ON ON ON OFF
17 OFF OFF OFF OFF ON
18 ON OFF OFF OFF ON
19 OFF ON OFF OFF ON
20 ON ON OFF OFF ON
21 OFF OFF ON OFF ON
22 ON OFF ON OFF ON
23 OFF ON ON OFF ON
24 ON ON ON OFF ON
25 OFF OFF OFF ON ON
26 ON OFF OFF ON ON
27 OFF ON OFF ON ON
28 ON ON OFF ON ON
29 OFF OFF ON ON ON
30 ON OFF ON ON ON
31 OFF ON ON ON ON
32 ON ON ON ON ON
Baud Rate Switch Setting
SW2-6 SW2-7 SW2-8
2400 OFF OFF OFF
4800 ON OFF OFF
9600 OFF ON OFF