ELECTRICAL
Input Voltage: 24 VAC required for pan/tilt
Power
Requirements: Running
Pan — .31 amp (7.5 vA)
Tilt — .38 amp (9.2 vA)
Starting
Pan — .47 amp (11.2 vA)
Tilt — .56 amp (13.5 vA)
Maximum
Current: 2 amps per conductor (SL models
only)
Connectors:
Pan/Tilt Amp CPC type (mate sup-
plied). Installed onto a pigtail exiting
from base of pan/tilt (all functions —
camera power, lens, video, pan/tilt).
Lens: Hirschmann MAB6100
Video: BNC
Camera Power: Spade lugs
Motors: Two-phase induction type. Continu-
ous duty, instantaneous reversing
Limit Switches: Pan — 5 amp
Tilt — 5 amp
External adjustment
Cable Distances: (See Section 8.2)
GENERAL
Construction: Aluminum
(Product specifications subject to change
without notice.)
15.0 PAN/TILT ASSEMBLIES
15.1 ASSEMBLY DESCRIPTION
The pan/tilt assembly is a “mini” light duty pan/tilt for
loads up to 15 lbs (6.8 kg) and is factory pre-wired for
all control functions (pan and tilt, motorized zoom lens,
24 VAC camera power, and video). All connections are
made at the input connector, eliminating the need for
wiring harnesses. This greatly reduces installation time,
while increasing reliability and serviceability.
15.2 ASSEMBLY MODELS
PT2801000ASSY Mini light-duty pan/tilt, 24 VAC, with
0-355° pan and tilt
PT2801001ASSY Mini light duty pan/tilt with 360° pan
rotation, 24 VAC
PT2801002ASSY Same as PT2801000ASSY except
with position feedback modification
which allows pan/tilt to be automati-
cally positioned to various preset
positions
PT2801003ASSY Same as PT2801001ASSY except
with position feedback modification
which allows pan/tilt to be automati-
cally positioned to various preset po-
sitions
16.0 ASSEMBLY SPECIFICATIONS
MECHANICAL
Pan: Movement in horizontal plane:
PT2801000ASSY,
PT2801002ASSY 0-355° @ 10°/sec ±1°
PT2801001ASSY,
PT2801003ASSY 360°
Tilt: ±90° movement in vertical plane at
3°/sec ±.5°
(no load condition)
Maximum Load: 15 lbs (6.8 kg)