Pelco ED29 Security Camera User Manual


 
4 PELCO Manual C460M-E (7/95)
Figure 3. Heater/Blower Wiring Diagram (120 VAC)
4.3 WIRING INSTRUCTIONS
Models ED28-1 and ED29-1
These models are supplied with a factory installed
heater/blower and service light. Supply 120 VAC
power for the heater/blower and wire according to
Figures 3.
Models ED2820-3, ED2820-3SL/PP,
ED2920-3, ED29-3
These models are supplied with factory-installed blower/
heater and service light. For installation, supply 230
VAC power for the blower/heater and wire according to
the diagram in Figure 4.
Models ED2820, ED2820-3, ED2820-SL,
ED2820-PP, ED2820SL/PP, ED2820-3SL/
PP, ED2920, and ED2920-SL
These Harris Dome models without receiver include the
PT2801000ASSY,PT2801001ASSY, PT2801002ASSY or
PT2801003ASSY pan/tilt assemblies which are pre-
wired for all control functions — pan/tilt, motorized
zoom lens, camera power (24 VAC) and video.
All connections are made at the input connector, elimi-
nating the need for wiring harnesses made in the field.
Wire the control cable per Section 9.3 using the appli-
cable wiring diagrams in Figures 16 through 18, and
supply the necessary power.
Models ED2820-RX, ED2820SL-RX,
ED2820-RX/PP, ED2820SL-RX/PP,
ED2920-RX and ED2920SL-RX
When wiring the dome models with integral Coaxitron
receiver listed above, connect the coax to the controller
and plug the receiver into a 120 VAC power supply.
In addition, the ED2820-RX/PP and ED2820SL-RX/
PP include preset position feedback capabilities. These
packages are equipped with PT2801002ASSY and
PT2801003ASSY pan/tilts and have the Coaxitron re-
ceiver installed and pre-wired to the pan/tilt. Since
these versions include 8 alarm inputs and 1 alarm
output, be sure to wire them according to the diagram in
Figure 6.
Models ED2820-WX and ED2820SL-WX
To wire Harris Dome models ED2820-WX and
ED2820SL-WX with integral Wiretron receiver, con-
nect the twisted pair and coax to the controller and plug
the receiver into a 120 VAC power supply.